Answer the following with respect to transformer design :
[7 marks]Why cores are stepped? (b) Why yoke is designed for low flux density?
[ marks]Calculate the diameter and length of armature for a 7.5 kW, 4 pole, 1000 rpm, 220 V Shunt motor. Full load efficiency=0.83, maximum gap flux density=0.9 Wb/m2, specific electric loading =30,000 ampere conductors per meter, field form factor=0.7, assume maximum efficiency occurs at full load and field current is 2.5% of rated current. The pole face is square.
[7 marks]Explain how the choice of number of poles in a d.c. machine affects : (1) Losses in the machine (2) Weight of machine
[7 marks]A 500 kW, 375 rpm, 8 pole D.C. generator has a flux per pole of 0.0885 wb. Determine the armature demagnetizing and cross-magnetizing mmf per pole if the brushes are given a lead of 5% of pole pitch. Assume power developed by armature to be equal to rating of machine.
[7 marks]A 350 kW, 500 V 450 rpm, 6 pole dc generator is built with an armature diameter of 0.87 m and core length of 0.32 m. The lap wound armature has 660 conductors. Calculate the specific electric and magnetic loadings.
[7 marks]Explain different methods used to improve armature reaction effect in DC machine.
[7 marks]Write a short note on a square and stepped cores in transformer design.
[7 marks]Discuss the behavior of current transformer under system short circuit condition.
[7 marks]Derive the expression for no load current of Transformer.
[7 marks]Explain various factors affecting choice of Average flux density and Ampere conductors per meter for D.C. machine.
[7 marks]Explain : (a) Significance of mitered joints in transformer.
[7 marks]Design difference between power & distribution transformer.
[ marks]Write a Short Note on : Duty Cycle
[7 marks]Derive output equation of 3 –Φ Transformer. Write the significance of constant ‘K’.
[7 marks]How will the output and losses in transformer change with the linear dimensions?
[7 marks]The ratio of flux to full load mmf in a 400 kVA, 50 Hz single phase core type power transformer is 2.4 x 10-6. Calculate the net iron area and the window area of transformer. Maximum flux density in the core is 1.3 Wb/m2, current density 2.7 A/mm2 and window space factor 0.26. Also calculate the full load mmf.1
[7 marks]What is design optimization? Derive necessary condition for designing a transformer with minimum cost.
[7 marks]A 40 Hz transformer is to be used on a 50 Hz system. Assuming the Steinmetz’s coefficient as 1.6 and losses at lower frequency 1.2%, 0.7% and 0.5% for I2R, hysteresis and eddy current respectively. Find losses on 50 Hz for the same supply voltage and current.
[7 marks]